Scoring and Timing systems for Athletics - IAAF Approved
Article: STAT
Manufacturer: Swiss Timing (Switzerland)
Category: Scoring and Timing systems
Specifications:
- For running disciplines used: false start detection system AC3 with E-Gun, running time scoreboard GEMINI, photocell ARGES, high speed and light sensitivity photo finish camera MYRIA, 3-sided Lap counter with custom branding Bell and etc.
- For technical disciplines used: Concentration clock BOREAS or LISTO, Electronic distance measurement – EDM, MISTRAL scoreboard with integrated ultrasonic wind sensor, The OIN5 full-colour matrix scoreboard
Sertifcates : IAAF Approved
Athletics false start detection system ASC3
Article: 3457.900
Manufacturer: Swiss Timing (Switzerland)
Model: ASC3 Automatic Start Control
Category: false start detection system
Specifications:
Suitable for all competition levels, Monitor up to 10 lanes simultaneously.
Acoustic signal in case of false start, Force curve display for each lane. On-line transfer data via a serial line. 115-230 VAC, internal battery (6 hours autonomy). Timer, headset, printer and Electronic starting system: E-gun are included
Sertifcates : IAAF Approved
Egun - StartTime V acoustic start device
Article: 3481.931
Main unit dimensions: 376 x 215 x 245mm w/o Connectors
Microphone dimensions: 118 x 25 x 80 mm. + 7 meter cable
E-GUN dimensions 280 x 35 x 140 mm + 7 meter cable
Alarm “low battery”: Yes, 4 levels indicated as battery symbol (Empty, Low, Medium, Full)
Protection class: IP41
Power: Built in 12 Volt / 7 Ah Sealed lead-acid battery
Standby time: 24 Hours (1000 starts). After this, the unit should still be operable for 1 hour.
The self-discharge time is approximately 12 months if not in use.
An external 12V Lead/Acid battery (car battery) connected to the charger input, could be used if extended operation time is needed.
Charger: Max. initial current: 1.0 Ah (only for use in dry environment).
Speakers: Load 3.2 - 16 Ohms
Output speakers: @13.2 Volts, 3.2 Ohms, 1 kHz Typical: 2 * 13 Watt with < 10 % Distortion Maximum: 2 * 19 Watts with 10 % Distortion
Storage temperature: -20ºC to +65ºC
Working temperature: -10ºC to +65ºC
Relative humidity: (20%-80%) without condensation
Manufacturer Swiss Timing (Switzerland)
Electronic distance measurement system
Article: 3142.902
Manufacturer: (Switzerland)
Category: Refereeing and timing systems for athletics
Specifications:
Weight : 6.5 kg
Battery life : 6 - 8 hours
Maximum range : 3000 m (prism)
250 m (reflective tape), 150 m (reflectorless)
Minimum range : 1.5 m
Accuracy : 2 mm
Measuring time : 1.5 s
Display: colored LCD
Interface language : selectable
Data connection : RS232 or optional Bluetooth
Operating temperature : -20 to 50°C (operating)
Storage temperature : -40 to 70°C (storage)
Humidity : 95% (non-condensing)
Sertifcates : IAAF Approved
False start detection system kit for Athletics
Article: 3508.900
Manufacturer: Swiss Timing (Switzerland)
Category: Scoring and Timing systems
Specifications:
- For running disciplines used: false start detection system Mostrac with E-Gun, StartTime V, Starter headset with microphone, Three loudspeaker (with 10 m of cable for each), 8 MoSen in their charger case, 16 fixing clips to stick directly on starting Block, Power supply to recharge StartTime and MoSen
ARGES photocells
Article: 3459.930
Manufacturer: Swiss Timing (Switzerland)
Model: Arges photocells
Category: Part of refereeing and timing systems
Specifications: Used for cross country, athletic and other sports.
Battery type: 3xAA or UM-3
Typical battery life: ~ 4 h (transmitter), ~ 20 h (receiver)
Weight incl. batteries: 915 g
Dimensions: 188 x 57 x 95 mm
Fixing: UNC 1/4”
Protection: IP54
Working temperature: -30°C to 70°C
Storage temperature: -35°C to 85°C
Operating distance: max 200 m
Response time: < 1 ms
Power supply : integrated 12V/7Ah lead-acid battery
Battery autonomy : more than 1000 starts before recharge
ARGES reflex photocell
Article: 3459.900
Battery type : 3xAA or UM-3
Average battery life : ~ 20h (with alkaline batteries)
Battery indicator : 4 levels battery symbol
Dimensions : 188 x 57 x 95 mm
Photocell weight : 915 g (incl. batteries)
Reflector weight : 160 g
Fixing : UNC 1/4" mounting thread
Operating temperature : -30°C to 70°C
Storage temperature : -40°C to 85°C
Operating distance : up to 30m
Response time : < 1 ms sensing time
Relative humidity : up to 95% (non-condensing)
Protection class : IP54
Manufacturer Swiss Timing (Switzerland).
MISTRAL Integrated wind gauge
Article: 3436.900
Measurement duration: 5, 10 or 13 seconds, 1 to 30 seconds with RS422 serial remote control
Display: Amber LED, 250mm height
Display luminosity: 4 steps automatically adjusted with a light sensor
Display duration: 3 minutes after each measurement
Power: 115 / 230VAC 50/60 Hz, max. 0.5A
Internal battery autonomy: ~12 hours* at maximum luminosity, ~60 hours* at minimum luminosity
Wind speed range: -9.9m/s to +9.9m/s
Wind speed accuracy: ±0.1m/s
Operating temperature: 0 °C to +50 °C
Storage temperature: -25 °C to +70 °C
Moisture protection: IP54 (IP65 for the head)
Dimensions (closed): 850 x 760 x 200 mm
Dimensions (maximum open): 850 x 1390 x 415 mm
Weight with head: 21 kg
Manufacturer Swiss Timing (Switzerland)
Remote wind gauge sirocco
Article: 3436.910
Manufacturer: Swiss Timing (Switzerland)
Category: Scoring and Timing systems component for athletics
Specifications:
Anemometer model Sirocco. Weight: 1.3 kg (without support, with cable)
Measurement duration : any, selectable through PC interface
Display: onto Scan’O’Vision camera PC
Range: -9.9 to +9.9 m/s
Accuracy : +/- 0.1 m/s
Data connection: Tu 7pF (RS422) (cable included)
Cable length: 5 m
Power: through optional INT131 unit
Operating temperature : -35 to +70°C
Certifications: IAAF demand compliance
OMEGA SCAN'O'VISION MYRIA 10 Camera
Article: 3503.910
Acquisition speed: 500 to 2’000 lines per seconds or 500 to 10’000 lines per seconds
Resolution: 2048 pixels (at any speed)
Nbr. of color per pixel: >16 millions
Time base precision: ±0.1ppm (oven-controlled)
Transmission: Ethernet 1Gb/s (PoE PD), 9kB jumbo frame, IEEE 802.3at (25W), IEEE 1588 (Precision Time Protocol)
Max. distance between camera and computer: 100m (Cat5e Ethernet cable)
Working temperature: 0°C to +50°C
Storage temperature: -20°C to +70°C
Protection: IP55
Camera dimension: 415 x 270 x 143mm (LxWxH)
Camera weight: 3.6 kg
Lens (included in camera housing)
Zoom ratio: 10x
Vertical field angle: 6.5° to 58.8°
Max. aperture: F1.4
Minimum object distance: 1.2m
Remote control: Zoom, Aperture, Focus
Manufacturer Swiss Timing (Switzerland)